Category Archives: 1.3 Alat Pemeriksaan

DOPPLER SONOTRAX

doppler

Spesifikasi:

1. FHR Measuring Range : 50 ~210BPM (BPM : beat /minute)
2. Resolution : 1 BPM
3. Accuracy : ± 3 BPM
4. Power consumption : <0.8W
5. Auto Shut-OFF : After 1 minute no signal, power off automatically
6. Battery Type Recommended : Two pieces of 1.5 v DC battery (size AA LR6)
7. Probe : Nominal Frequency : 2.0 Mhz
8. Working Frequency : 2.0 Mhz±10%
9. P-: <1Mpa
10. 1₀b<20 mW/cm²
11. I spta : <100mW/cm²

DOPPLER GL-500B

doppler

Spesifikasi:

1. Normal working condition :
     a) Environment condition
          – Ambient temperature : 5oC ~40oC
          – Relativity humidity : £ 80%
          – Athmospheric pressure : 860hPa ~ 1060 hPa
     b) Electric Source of Charge
          – Special charge  : 100 V ~240 V (AC)
          – Frequency  : 50 Hz ~ 60 Hz
2. Ultrasonic frequency output   : 2.5 MHz
3. Integrated sensitivity  : ³90 db
4. Continue working time    : ³ 8 hr
5. Numeric code display  : 0-60 second and zero-resetting stopwatch
     Stopwatch Precission  : ± 1 s/d 30 minutes
6. Heart rate exam. scope    : 65 ~ 210 bpm
     Resolution  : 1 bpm
7. High energy Ni-MH AAA rechareable battery
8. Dimensions of main unit    : 118 x 64 x 44 mm
9. Weight : 0.3 Kg
10. Peak negative pressure    : £ 1MPa
        Output beam intensity    : £ 20 mW/cm2
        Spatial-peak temporal-average
        Intensity  : £ 100 mW/cm2
11. Instrument Equipped :
       Main Unit  1 set,  Probe  1 pc,   Spiral wire  1 pc
       Charge  1 pc,  Manual  1 pc,  Ultrasonic Gel  1 tube

DOPPLER GL-500A

doppler

Spesifikasi:

1. Normal working condition :
     a) Environment condition
          – Ambient temperature : 5oC ~40oC
          – Relativity humidity : £ 80%
          – Athmospheric pressure : 860 hPa ~ 1060 hPa
     b) Electric Source of Charge
          – Special charge : 100 V ~ 240 V (AC)
          – Frequency : 50 Hz ~ 60 Hz
2. Ultrasonic frequency output : 2.5 MHz
3. Integrated sensitivity : ³90 db
4. Continue working time : ³ 8 hr
5. Heart rate exam. scope : 65 ~ 210 bpm
     Resolution : 1 bpm
6. High energy Ni-MH AAA rechareable battery
7. Dimensions of main unit : 118 x 64 x 44 mm
8. Weight : 0.3 Kg
9. Peak negative pressure : £ 1MPa
     Output beam intensity    : £ 20 mW/cm2
     Spatial-peak temporal-average
     Intensity  : £ 100 mW/cm2
10. Instrument Equipped :
        Main Unit 1 set, Probe 1 pc, Spiral wire 1 pc
        Charge 1 pc, Manual 1 pc, Ultrasonic Gel 1 tube

DOPPLER GL-500

doppler

Spesifikasi:

Main Technical Index :
1. Normal working condition :
     – Environment condition : 5oC ~ 40oC
     – Relativity humidity : £ 80%
     – Atmoshperic pressure :700 hPa ~1060 hPa
2. Ultrasonic frequency output : 2.5 MHz
3. Power output £ mW/cm2
4. Integrated sensitivity : ³ 100 dB
5. 6F22 9 V dry battery
6. Sound output : 0.5 W
7. Dimension of main unit : 75 x 60 x 35 mm
8. Dimensions of probe : Æ 53 x 27 mm

Componen List :

– Main Unit  1 set
– Probe  1 pc
– 6F22 9 V dry battery  1 pc
– Ultrasonic Gel  1 tube
– Usage Brochure  1 set